Operation Theater Tables
Maquet Datascope CS100
The Datascope CS100 is a highly customizable balloon pump system that allows caregivers to deliver the best care in a variety of situations. The unit has three modes of operation: Automatic, Semi-Automatic and Manual. This allows caregivers to use the C100 to manually operate the pump, or set up the unit to offer automatic specialized therapy.
The laptop-style display and keypad easily fold up and detach, allowing clinicians to remotely monitor patients.
Features
Maquet Datascope CS100
- Maquet CS100 IABP comes with with IntelliSync offers one-button start up, automatically adapting to changing conditions, making it the right choice for any patient condition.
- Automatically evaluates and selects optimal trigger source and lead
- Sets inflation at the dicrotic notch and deflates IAB at the start of systole
- Responds to changes in signal quality by selecting new trigger source Automated trigger source and timing management provide continuous, consistent support for your patient.
- Fast, one-button start-up automatically conducts autofill and initiates 1:1 assist.
- Full color, high contrast display tilts for easy viewing.
- Display and keypad in laptop-style configuration, allowing caregivers to fold and detach the unit for remote operation. Easy-to-use keypad with an intuitive user interface.
- Customizable display panel allows operators to adjust sweep speed, brightness, balloon waveform, and inflation markers.
- Switch easily between three operation modes: Automatic, Semi-Automatic and Manual.
- Automatically evaluates and selects optimal trigger source and lead.
- System detects changes and easily adapts to new patient rhythms.
- Fully annotated printouts with user-configurable waveforms and strip lengths.
- Locking casters and durable design keep the CS100 secure in a variety of settings.
Specification
Maquet Datascope CS100
Dimensions
- Height: 30 in (76.2 cm)
- Width: 22.5 in (57.2 cm)
- Depth: 13.2 in (33.5 cm)
- On Cart
- Height: 42.2 in (114.8 cm)
- Width: 17.6 in (44.7 cm)
- Depth: 23.4 in ( 59.4 cm)
- Off Cart
- Height: 28.2 in (71.6 cm)
- Width: 11.3 in (28.7 cm)
- Depth: 21.5 in ( 54.6 cm)
- Monitor weight: 9.5 lbs (4.3 kg)
- Console weight: 133.2 lbs ( 60.4 kg)
Color Display
- Width:8.3 in (21cm)
- Height: 6.2 in (15.8 cm)
- viewing angle:
- Up: 45°
- Down 55°
- Right 70°
- Left 70°
- Rotates 330°
- Tilts180°
- Detachable Laptop-like closure for storage and protection
Power
- Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%
- Mains Frequency: 50/60 Hz ± 3 Hz
- Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, 3 hrs.(approx. @ 90 bpm)
- Battery Type: Maintenance free; Sealed lead-acid
General information
- ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
- Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
- Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to Monitor)
- Defibrillator Protection: Discharge levels 360 J (trace returns to screen in 5 sec. max)
Operating Conditions
- Operating Temperature: 10°C – 40°C
- Operating Humidity: 5 – 95% (R.H.) non-condensing
- Operating Altitude: 0 – 12,000 feet (3,657 m); automatic altitude correction for IAB pressure
Operating Modes
- ECG Trigger: Threshold dynamically adjusted by system for high sensitivity and selectivity of the R-wave detection; Minimum = 120μV ± 20μV at normal gain; 40μV at max. gain
- Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the difference between peak systolic and end diastolic (avg. over multiple cycles); In variable mode: User adjustable between 7 and 30 mmHg ± 3 mmHg
- Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
- Pacer V/A-V Trigger: V Pacer: fixed at rate up to 185 bpm (no demand pacing) A-V Pacer: fixed at rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
- Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm
- Tall T-Wave Rejection: Rejects all T-Waves where Q-T interval is <300 ms and the amplitude is <70% of QRS input amplitude
- Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and durations between 0.1 ms to 2.0 ms with: 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV